Sensör
Fotoelektrik Sensör
Fiber Optic Sensor
Fiber Optik Sensör
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Fotoelektrik Sensör
Pepperl Fuchs Fiber Optic Sensor
Pepperl Fuchs Fiber Optik Sensör
Pepperl Fuchs SU19/102/115/126a
Pepperl SU19/102/115/126a
SU19/102/115/126a
Pepperl Fuchs SU19/102/115/126a Fiber Optik Sensör
Pepperl SU19/102/115/126a Fiber Optic Sensor
Fotoelektrik Sensör Pepperl Fuchs SU19/102/115/126a
Pepperl Fuchs SU19/102/115/126a Fotoelektrik Sensör
Fiber Optic Sensor SU19/102/115/126a Pepperl-Fuchs
Fiber Optik Sensör SU19/102/115/126a Pepperl-Fuchs
Ürün Açıklaması |
Classic Series fiber optic sensor with display, master module, NPN output, fixed cable |
General specifications | ||
Sensor range | up to 150 mm (KLR-C02-2,2-2,0-K146) | |
Detection range | up to 450 mm (KLE-C01-2,2-2,0-K116) | |
Light source | LED | |
Light type | modulated visible red light , 660 nm | |
Ambient light limit | 10000 Lux | |
Gang mounting | maximum 20 units | |
Functional safety related parameters | ||
MTTFd | 500 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | Power on: static illumination , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) | |
Diagnostics indicator | 7-segment display | |
Function indicator | LED yellow: static illumination switching state, flashes when falling short of the stability control | |
Control elements | Button (Mode) for menu choice ; Button (Set) for Teach-In ; Button (Up/Down) for fine adjusting and parameterization | |
Electrical specifications | ||
Operating voltage | 10 … 30 V DC | |
Ripple | 10 % | |
No-load supply current | ≤ 30 mA | |
Output | ||
Pre-fault indication output | 1 NPN, short-circuit protected open collector | |
Switching type | light/dark on selectable programmable | |
Signal output | 1 NPN, short-circuit protected open collector | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Voltage drop | ≤ 2 V DC at 100 mA ; ≤ 0.7 V at 10 mA | |
Switching frequency | High speed mode: 16 kHz , Standard mode: 3 kHz , High resolution: 250 Hz ~ 3 kHz (selection by the sensor), Automatic: 250 Hz , Glass mode: 250 Hz | |
Response time | High speed mode: 30 µs , Standard mode: 160 µs , High resolution: 2 ms , Automatic: 160 µs ~ 2 ms (choice by the sensor), Glass mode: 2 ms | |
Repeat accuracy | ≤ 0.5 % of adjusted sensor range | |
Timer function | ON-delay, OFF-delay, one shot, pulse extension ; adjustable 0 … 999 ms in 1 ms increments | |
Compliance with standards and directives | ||
Standard conformity | ||
Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Approvals and certificates | ||
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -10 … 55 °C (14 … 131 °F) | |
Storage temperature | -20 … 70 °C (-4 … 158 °F) | |
Mechanical specifications | ||
Housing width | 9 mm | |
Housing height | 34.5 mm | |
Housing depth | 62.3 mm | |
Degree of protection | IP50 | |
Connection | 2 m PVC cable, 4 x 0,14 mm2 | |
Material | ||
Housing | PC | |
Mass | 45 g |