Sensör
Fotoelektrik Sensör
Nirengi Sensör
Photoelectric Triangulation Sensor
Fotoelektrik Nirengi Sensör
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Fotoelektrik Sensör
Pepperl Fuchs Nirengi Sensör
Pepperl Fuchs Triangulation Sensor
Pepperl Fuchs Photoelectric Triangulation Sensor
Pepperl Fuchs OQT400-R201-2EP-IO-V1
Pepperl OQT400-R201-2EP-IO-V1
OQT400-R201-2EP-IO-V1
Pepperl Fuchs OQT400-R201-2EP-IO-V1 Fotoelektrik Nirengi Sensör
Pepperl OQT400-R201-2EP-IO-V1 Photoelectric Triangulation Sensor
Fotoelektrik Sensör Pepperl Fuchs OQT400-R201-2EP-IO-V1
Pepperl Fuchs OQT400-R201-2EP-IO-V1 Fotoelektrik Sensör
Triangulation Sensor OQT400-R201-2EP-IO-V1 Pepperl-Fuchs
Nirengi Sensör OQT400-R201-2EP-IO-V1 Pepperl-Fuchs
Ürün Açıklaması |
Measuring sensor with multiple switch points |
General specifications | ||
Detection range | 40 … 400 mm | |
Detection range min. | 40 … 100 mm | |
Detection range max. | 40 … 400 mm | |
Adjustment range | 100 … 400 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Black/White difference (6 %/90 %) | < 5 % | |
Diameter of the light spot | approx. 15 mm at a distance of 400 mm | |
Angle of divergence | approx. 2.5 ° | |
Ambient light limit | EN 60947-5-2 : 70000 Lux | |
Functional safety related parameters | ||
MTTFd | 600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on – power on flashing (4Hz) – short circuit flashing with short break (1 Hz) – IO-Link mode |
|
Function indicator | LED yellow: constantly on – switch output active constantly off – switch output inactive |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 10 … 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile | Identification and diagnosis Smart Sensor type 0 |
|
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 2.3 ms | |
Process data witdh | Process data input 2 Bit Process data output 2 Bit |
|
SIO mode support | yes | |
Device ID | 0x111811 (1120273) | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q – Pin4: NPN normally open, PNP normally closed, IO-Link Q2 – Pin2: NPN normally open, PNP normally closed |
|
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Switching frequency | 217 Hz | |
Response time | 2.3 ms | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -40 … 60 °C (-40 … 140 °F) | |
Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
Mechanical specifications | ||
Housing width | 15 mm | |
Housing height | 61.7 mm | |
Housing depth | 41.7 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | 4-pin, M12 x 1 connector, 90° rotatable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 47 g |