Ürün Açıklaması |
Measuring sensor with multiple switch points, small design, background suppression and more adjustable operating modes, IO-Link interface |
General specifications | ||
Detection range | 5 … 120 mm | |
Detection range min. | 5 … 20 mm | |
Detection range max. | 5 … 120 mm | |
Adjustment range | 20 … 120 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Black/White difference (6 %/90 %) | < 5 % at 120 mm | |
Diameter of the light spot | approx. 8 mm at a distance of 120 mm | |
Angle of divergence | approx. 4 ° | |
Ambient light limit | EN 60947-5-2 : 30000 Lux | |
Functional safety related parameters | ||
MTTFd | 600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on – power on flashing (4Hz) – short circuit flashing with short break (1 Hz) – IO-Link mode |
|
Function indicator | LED yellow: constantly on – switch output active constantly off – switch output inactive |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 10 … 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile | Smart Sensor | |
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 2.3 ms | |
Process data witdh | Process data input 2 Bit Process data output 2 Bit |
|
SIO mode support | yes | |
Device ID | 0x110803 (1116163) | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q – Pin4: NPN normally open, PNP normally closed, IO-Link Q2 – Pin2: NPN normally open, PNP normally closed |
|
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Switching frequency | 217 Hz | |
Response time | 2.3 ms | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
Ambient conditions | ||
Ambient temperature | -40 … 60 °C (-40 … 140 °F) | |
Storage temperature | -40 … 70 °C (-40 … 158 °F) | |
Mechanical specifications | ||
Housing width | 15 mm | |
Housing height | 43.9 mm | |
Housing depth | 26.7 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | M8 x 1 connector, 4-pin | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 12 g |