Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NJ2,5-14GM-N-V1-Y21146
Pepperl NJ2,5-14GM-N-V1-Y21146
NJ2,5-14GM-N-V1-Y21146
Pepperl Fuchs NJ2,5-14GM-N-V1-Y21146 Endüktif Sensör
Pepperl NJ2,5-14GM-N-V1-Y21146 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NJ2,5-14GM-N-V1-Y21146
Pepperl Fuchs NJ2,5-14GM-N-V1-Y21146 Yakınlık Sensörü
Inductive Sensor NJ2,5-14GM-N-V1-Y21146 Pepperl-Fuchs
Endüktif Sensör NJ2,5-14GM-N-V1-Y21146 Pepperl-Fuchs
General specifications | ||
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2.5 mm | |
Installation | flush | |
Assured operating distance | 0 … 2.02 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 … 1500 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | ≤ 1 mA | |
Functional safety related parameters | ||
MTTFd | 5887 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | 0 … 90 °C (32 … 194 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |