Ürünler

Ultrasonic Sensor Pepperl Fuchs
Endüktif Sensör Pepperl Fuchs NBN40-L2-A2-V1
19 Ocak 2019
Pepperl Fuchs Ultrasonic Sensor
Endüktif Sensör Pepperl Fuchs NBN5-11K8-N-V8
19 Ocak 2019
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NBN40-L2-A2-V1-3G-3D


Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBN40-L2-A2-V1-3G-3D
Pepperl NBN40-L2-A2-V1-3G-3D
NBN40-L2-A2-V1-3G-3D

Açıklama

Pepperl Fuchs NBN40-L2-A2-V1-3G-3D Endüktif Sensör
Pepperl NBN40-L2-A2-V1-3G-3D Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBN40-L2-A2-V1-3G-3D
Pepperl Fuchs NBN40-L2-A2-V1-3G-3D Yakınlık Sensörü
Inductive Sensor NBN40-L2-A2-V1-3G-3D Pepperl-Fuchs
Endüktif Sensör NBN40-L2-A2-V1-3G-3D Pepperl-Fuchs

Teknik veriler NBN40-L2-A2-V1-3G-3D

General specifications
Switching function complementary
Output type PNP
Rated operating distance 40 mm
Installation non-flush
Output polarity DC
Assured operating distance 0 … 32.4 mm
Actual operating distance 36 … 44 mm
Reduction factor rAl 0.31
Reduction factor rCu 0.3
Reduction factor r304 0.74
Reduction factor rBrass 0.39
Output type 4-wire
Nominal ratings
Operating voltage 10 … 30 V DC
Switching frequency 0 … 180 Hz
Hysteresis typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop ≤ 2 V
Operating current 0 … 200 mA
Off-state current 0 … 0.5 mA
No-load supply current ≤ 20 mA
Time delay before availability 80 ms
Operating voltage indicator LED, green
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1057 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection class II
Rated insulation voltage 253 V
Rated impulse withstand voltage 4000 V
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 … 85 °C (-13 … 185 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material PA
Sensing face PA
Degree of protection IP69K
Mass 130 g
Data for application in connection with hazardous areas
Equipment protection level Gc (nA) , Dc
Equipment protection level Gc (nA)
Type of protection “n”
CE marking [*PD-Z02586A*]
Certificates
ATEX certificate PF15CERT3754X
ATEX marking II 3G Ex nA IIC T6 Gc
Standards EN 60079-0:2012+A11:2013 , EN 60079-15:2010
Possible characteristics maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F)
at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F)
at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F)
at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
Equipment protection level Dc
Type of protection Protection by enclosure “tc”
CE marking [*PD-Z02586A*]
Certificates
ATEX certificate PF15CERT3774X
ATEX marking II 3D Ex tc IIIC T80°C Dc
Standards EN 60079-0:2012+A11:2013 , EN 60079-31:2014
Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F)
at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F)
at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F)
at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
General information
Use in the hazardous area see instruction manuals