Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBN30-U4-Z2
Pepperl NBN30-U4-Z2
NBN30-U4-Z2
Pepperl Fuchs NBN30-U4-Z2 Endüktif Sensör
Pepperl NBN30-U4-Z2 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBN30-U4-Z2
Pepperl Fuchs NBN30-U4-Z2 Yakınlık Sensörü
Inductive Sensor NBN30-U4-Z2 Pepperl-Fuchs
Endüktif Sensör NBN30-U4-Z2 Pepperl-Fuchs
General specifications | ||
Switching function | Normally open/closed (NO/NC) | |
Output type | Two-wire | |
Rated operating distance | 30 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 … 24.3 mm | |
Actual operating distance | 27 … 33 mm typ. 30 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.7 | |
Output type | 2-wire | |
Nominal ratings | ||
Operating voltage | 5 … 60 V | |
Switching frequency | 0 … 150 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | yes | |
Voltage drop | ≤ 5 V | |
Voltage drop at IL | ||
Voltage drop IL = 100 mA, switching element on | … 5 V | |
Operating current | 2 … 200 mA | |
Off-state current | 0 … 0.5 mA | |
Switching state indicator | 2 LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1170 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
|
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 … 85 °C (-13 … 185 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
|
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PA/metal with epoxy powder coating | |
Sensing face | PA | |
Housing base | metal | |
Degree of protection | IP68 / IP69K | |
Mass | 225 g | |
Note | Tightening torque: 1.8 Nm (housing) |