Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBB2-V3-E2-Y244942
Pepperl NBB2-V3-E2-Y244942
NBB2-V3-E2-Y244942
Pepperl Fuchs NBB2-V3-E2-Y244942 Endüktif Sensör
Pepperl NBB2-V3-E2-Y244942 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBB2-V3-E2-Y244942
Pepperl Fuchs NBB2-V3-E2-Y244942 Yakınlık Sensörü
Inductive Sensor NBB2-V3-E2-Y244942 Pepperl-Fuchs
Endüktif Sensör NBB2-V3-E2-Y244942 Pepperl-Fuchs
General specifications | |
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 2 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 … 1.62 mm |
Reduction factor rAl | 0.35 |
Reduction factor rCu | 0.2 |
Reduction factor r304 | 0.7 |
Nominal ratings | |
Operating voltage | 10 … 30 V DC |
Switching frequency | 0 … 1000 Hz |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ≤ 3 V |
Operating current | 0 … 100 mA |
Off-state current | 0 … 0.5 mA typ. 0.1 µA at 25 °C |
No-load supply current | ≤ 15 mA |
Switching state indicator | LED, yellow |
Functional safety related parameters | |
MTTFd | 3560 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions | |
Ambient temperature | -25 … 70 °C (-13 … 158 °F) |
Mechanical specifications | |
Connection type | cable PVC , 130 mm Insulated wire end ferrule with 8 mm pin length |
Core cross-section | 0.14 mm2 |
Housing material | PBT |
Sensing face | PBT |
Degree of protection | IP67 |