Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBB2-12GM40-Z0-3G-3D
Pepperl NBB2-12GM40-Z0-3G-3D
NBB2-12GM40-Z0-3G-3D
Pepperl Fuchs NBB2-12GM40-Z0-3G-3D Endüktif Sensör
Pepperl NBB2-12GM40-Z0-3G-3D Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBB2-12GM40-Z0-3G-3D
Pepperl Fuchs NBB2-12GM40-Z0-3G-3D Yakınlık Sensörü
Inductive Sensor NBB2-12GM40-Z0-3G-3D Pepperl-Fuchs
Endüktif Sensör NBB2-12GM40-Z0-3G-3D Pepperl-Fuchs
General specifications | ||
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 … 1.62 mm | |
Actual operating distance | 1.8 … 2.2 mm typ. | |
Reduction factor rAl | 0.18 | |
Reduction factor rCu | 0.12 | |
Reduction factor r304 | 0.67 | |
Nominal ratings | ||
Operating voltage | 5 … 60 V DC | |
Switching frequency | 0 … 1000 Hz | |
Hysteresis | 1 … 10 typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | pulsing | |
Voltage drop | ≤ 5 V | |
Operating current | 2 … 100 mA | |
Lowest operating current | 2 mA | |
Off-state current | 0 … 0.5 mA typ. | |
Switching state indicator | all direction LED, yellow | |
Functional safety related parameters | ||
MTTFd | 2250 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Cable version | PA | |
Core cross-section | 0.14 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Gc (nA) | ||
Certificate of Compliance | PF 15CERT3754 X | |
Special conditions | ||
Protection against transients | Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded. | |
Equipment protection level Dc (tc) | ||
Instruction | Manual electrical apparatus for hazardous areas | |
Device category 3D | for use in hazardous areas with combustible dust | |
Certificate of Compliance | PF 15CERT3774 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. |
|
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure “tc” Some of the information in this instruction manual is more specific than the information provided in the datasheet. |
|
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Installation, commissioning | Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! | |
Maintenance | No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. |
|
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. |
|
Maximum operating voltage UBmax | The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
|
at UBmax=60 V, IL=100 mA | 45 °C (113 °F) | |
at UBmax=60 V, IL=50 mA | 54 °C (129.2 °F) | |
at UBmax=60 V, IL=25 mA | 59 °C (138.2 °F) | |
Protection from mechanical danger | The sensor must not be exposed to ANY FORM of mechanical danger. | |
Protection from UV light | The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. | |
Protection of the connection cable | The connection cable must be prevented from being subjected to tension and torsional loading. | |
Electrostatic charge | Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G; 3D |