Ürün Açıklaması |
Thru-beam sensor, 20 m detection range, red light, light/dark on, DC version, NPN output, sensitivity adjuster, emitter switch-off, fixed cable |
System components | ||
Emitter | M100-RT/35/76b/115 | |
Receiver | MV100-RT/35/102/115 | |
General specifications | ||
Effective detection range | 0 … 20 m | |
Threshold detection range | 30 m | |
Light source | LED | |
Light type | modulated visible red light | |
Diameter of the light spot | approx. 2 m at a distance of 30 m | |
Angle of divergence | approx. 2 ° | |
Functional safety related parameters | ||
MTTFd | 860 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | Receiver: LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted | |
Control elements | sensitivity adjustment | |
Control elements | Light-on/dark-on changeover switch | |
Electrical specifications | ||
Operating voltage | 10 … 30 V DC | |
Output | ||
Switching type | The switching type of the sensor is adjustable. The default setting is: light on | |
Signal output | 1 NPN output, short-circuit protected, reverse polarity protected, open collector | |
Compliance with standards and directives | ||
Directive conformity | ||
EMC Directive 2004/108/EC | EN 60947-5-2:2007+A1:2012 | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | 2 m fixed cable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA |