Ürünler

Debimetre Krohne H-250-RR-M9
Manyetik Endüktif Debimetre Krohne OPTIFLUX 4300 C DN25
25 Ocak 2019
Debimetre Krohne H-250-RR-M9
Proses Basınç Transmitteri Krohne OPTIBAR PC 5060 C
25 Ocak 2019
Tümünü Göster

Manyetik Endüktif Debimetre Krohne OPTIFLUX 4300 C Ex DN80


Debimetre
Flowmeter
Manyetik Debimetre
Magnetic Flowmeter
Manyetik Endüktif Debimetre
Magnetic Inductive Flowmeter
Krohne
Krohne Debimetre
Krohne Flowmeter
Krohne Manyetik Debimetre
Krohne Magnetic Flowmeter
Krohne Manyetik Endüktif Debimetre
Krohne Magnetic Inductive Flowmeter
Krohne OPTIFLUX 4300
Krohne OPTIFLUX 4300 C Ex DN80

Açıklama

Krohne OPTIFLUX 4300 C Ex DN80 Manyetik Endüktif Debimetre
Magnetic Inductive Flowmeter Krohne OPTIFLUX 4300 C Ex DN80

Teknik Veriler

KROHNE-Magnetic inductive flowmeter

Type OPTIFLUX 4300 C Ex

Primary head OPTIFLUX 4000

Compact model

Meter size DN 80|3″

Connection 3″ ASME B 16.5 300 lb RF

Overall dimension 250 mm|9.84″, excl. gaskets

& rings

Flange material Steel ASTM A 105 N

Product temperature -10…+140°C|+14…+285°F.

depending on pressure.

Housing Sheet metal

Lining PFA

Electrodes Hastelloy C22

fixed electrodes

with 2 electrodes construction

Insulat. class of coils H

Explosion protection FTZÚ 13ATEX 0093 X

Ex II 2(1)G Ex db e [ia Ga] IIC T6…T3 Gb

II 2D Ex tb IIIC T 150°C Db; IP66/67

Protection class IP 66/67 W (NEMA 4X/6) acc. EN 60529

Installation instruction multi-language

Tagplate 67 x 25 mm|2.64 x 0.98″

Material 316|1.4401

Tagno. see application data

Calibration GK

Finish KROHNE standard (KROHNE Grey)

PED group 1 – gases

CE / NOBO marking

APPLICATION DATA

Measuring range Std

Tag no. 45FT5350301

KROHNE flow converter

Type IFC 300 C Ex

Compact model

with 3 x 100% diagnostic

Empty pipe detection, conductivity

Incl. software PACTWARE

Accuracy see TDS

Power supply 100-230 V AC, 50/60 Hz

(85-250 V) – [22 VA]

Ex-protection Ex II 2 G

Flameproof enclosure “d”

Threaded connection 2 x M20 x 1,5

1 x M20 x 1,5 with blindplug

Operation manual English (USA)

Programming English

Process diagnostic Standard

Gas content, function of electrodes,

flowprofile, temperature.

Converter housing Standard, aluminum

Protection class IP 66/67 (NEMA 4X/6) acc. EN 60529

Communication Basic I/O

  1. Current output HART, active / passive
  2. Pulse / status outp. passive
  3. Status output passive
  4. Status out/control in passive

Certificate ALTO / sub pos. 1 pcs

Certificates per order position

Type OPTIFLUX 4000

Material List 3.1 certificate of pressure

retaining parts > 3

Calibration Calibration certificate

Language German or english

Meter size DN 20-40|¾-1½”