Ürünler

ABB 3HAA0001-ADY
ABB Robot Fren Kontrol Kartı E-lux Electronics 3HAA0001-ADX-1
17 Kasım 2016
Phoenix Contact 2723217
Interbus Phoenix Contact IBS ISA SC-RI-I-T 2723217
17 Kasım 2016
Tümünü Göster

Interbus Murr Elektronik Bus Module MBV-I 55461


Interbus
Interbus Bus Modül
Murr Interbus
Murr
Murr Interbus Bus Modül
Murr MBV-I
Murr MBV-I DO8/2A
Murr MBV-I DI8
Murr MBV-I 55461
Murr MBV-I 55460
Murr 55461
Murr 55460

Açıklama

MURR ELEKTRONİK Bus module
Murr MBV-I INTERBUS
Murr 55461

MURR MVK-MI DO8/2A Art.No. 55 46100
MURR MVK-MI DI8 Art.No. 55 46000

General

Interbus Slave IP67 with

8 digital outputs

EMC

EN 61131-2 Product standard

EN 61000-4-2 ESD ………………………………………………………….. Contact ± 4 kV, air ± 8 kV

EN 61000-4-3 RF- Field & GSM ………………………………………. 10 V/m

EN 61000-4-4 Burst …………………………………………………………. ± 2 kV

EN 61000-4-5 Surge ………………………………………………………… asym./symm. ± 500 V (DC net input)

asym. ± 1 kV (Signal connections)

EN 61000-4-6 HF-asymmetric ………………………………………….. 10 V

EN 61000-4-8 Magnetic field 50 Hz ………………………………….. 30 A/m

EN 55011 Emission ………………………………………………………….. QP 40 dBμV/m (30 – 230 MHz)

………………………………………………………………………………………. QP 47 dBμV/m (230 – 1000 MHz) (class A)

Ambient conditions

Operating temperature ……………………………………………………… 0°C … +55°C

Storage temperature …………………………………………………………. -25°C … +70°C

Enclosure type according to EN60529 ……………………………….. IP 67

Mechanical ambient conditions

Oscillation according to EN 60068 Part 2-6 ………………………… 10 – 58 Hz; const. amplitude 0,35 mm

………………………………………………………………………………………. 58 – 150 Hz; const. acceleration 20 g

Shock according to EN 60068 Part 2-27 ……………………………… Amplitude 50 g, 11 ms duration

Connection possibilities

Supply cable …………………………………………………………………… 2 x connector 7/8″ (male and female connector)

Data cable ………………………………………………………………………. 2 x M12 connector 5-pin

(male and female connector reverse-key coding)

Inputs and diagnosis inputs………………………………………………… 8 x 5-pin M12 female connectors

Miscellaneous

Dimensions (LxWxH) ………………………………………………………. 225 x 63 x 39 mm

Mounting dimension…………………………………………………………. 208,5 ±0,5 mm

Weight …………………………………………………………………………… 760 g

Bus data

Transfer protocol …………………………………………………………….. Interbus-S acc. to DIN 19245

Transfer rates ………………………………………………………………….. 500 kBaud

Galvanic isolation ……………………………………………………………. 500 V between bus and internal logic

Ident. number ………………………………………………………………….. 03 hex

Power supply

Operation voltage UB ……………………………………………………….. 24 V DC

Operation voltage range ……………………………………………………. 18 … 30 V DC

Current consumption (without inputs)…………………………………. <= 120 mA

Sensor supply ………………………………………………………………….. max. 200 mA per socket

Short circuit protection for sensors …………………………………….. Multi-fuse,

up to 100 mA load: automatic start-up

from 100 mA load: a reset is required

Multi-fuse reaction time (time to trip) ………………………………… 1s at IK >= 1 A and 23 °C

Connector ……………………………………………………………………… 7/8” (Max.1,5 mm2)

Reverse polarity protection, inputs …………………………………….. yes

Outputs

Actuator current load ……………………………………………………….. max. 2 A per actuator

Cable length…………………………………………………………………….. With 0,75 mm² max. 10 m

With 0,34 mm² max. 5 m

Connector ……………………………………………………………………… M12 (Max.0,75 mm2)

Cycle frequency……………………………………………………………….. max. 50 Hz

Lamp load……………………………………………………………………….. max. 10 W