Ürünler

Pepperl Fuchs Ultrasonic Sensor
Endüktif Sensör Pepperl Fuchs NBB15-U4-Z2
28 Aralık 2018
Pepperl Ultrasonik Sensörler
Endüktif Sensör Pepperl Fuchs NBB15-U4K-N0-V1
28 Aralık 2018
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NBB15-U4K-N0


Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBB15-U4K-N0
Pepperl NBB15-U4K-N0
NBB15-U4K-N0

Açıklama

Pepperl Fuchs NBB15-U4K-N0 Endüktif Sensör
Pepperl NBB15-U4K-N0 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBB15-U4K-N0
Pepperl Fuchs NBB15-U4K-N0 Yakınlık Sensörü
Inductive Sensor NBB15-U4K-N0 Pepperl-Fuchs
Endüktif Sensör NBB15-U4K-N0 Pepperl-Fuchs

Teknik veriler NBB15-U4K-N0

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 15 mm
Installation flush
Assured operating distance 0 … 12.15 mm
Actual operating distance 13.5 … 16.5 mm typ. 15 mm
Reduction factor rAl 0.33
Reduction factor rCu 0.31
Reduction factor r304 0.74
Output type 2-wire
Nominal ratings
Nominal voltage 8 V
Switching frequency 0 … 300 Hz
Hysteresis typ. 5 %
Reverse polarity protection yes
Short-circuit protection yes
Current consumption
Measuring plate not detected min. 2.2 mA
Measuring plate detected ≤ 1 mA
Switching state indicator LED, yellow
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibility NE 21:2007
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 … 100 °C (-13 … 212 °F)
Storage temperature -40 … 100 °C (-40 … 212 °F)
Mechanical specifications
Connection type screw terminals
Core cross-section ≤ 2.5 mm2
Housing material PA/metal
Sensing face PA
Degree of protection IP68 / IP69K
Mass 225 g
Note Tightening torque: 1.8 Nm (housing)
Equipment protection level Ga
CE marking [*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6…T1 Ga
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Ignition protection “Intrinsic safety”
Use is restricted to the following stated conditions
Appropriate type NBB15-U.K-N0…
Effective internal capacitance max. 110 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 200 µH ; a cable length of 10 m is considered.
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking [*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6…T1 Ga
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection “Intrinsic safety”
Use is restricted to the following stated conditions
Appropriate type NBB15-U.K-N0…
Effective internal capacitance max. 110 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 200 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Gc (ic)
Certificate PF 13 CERT 2895 X
CE marking [*PD-Z02586A*]
ATEX marking II 3G Ex ic IIC T6…T1 Gc
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection category “ic”
Use is restricted to the following stated conditions
Effective internal capacitance max. 110 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 200 µH ; A cable length of 10 m is considered.
Special conditions
for Pi=34 mW, Ii=25 mA, T6 73 °C (163.4 °F)
for Pi=34 mW, Ii=25 mA, T5 88 °C (190.4 °F)
for Pi=34 mW, Ii=25 mA, T4-T1 100 °C (212 °F)
for Pi=64 mW, Ii=25 mA, T6 66 °C (150.8 °F)
for Pi=64 mW, Ii=25 mA, T5 81 °C (177.8 °F)
for Pi=64 mW, Ii=25 mA, T4-T1 100 °C (212 °F)
for Pi=169 mW, Ii=52 mA, T6 45 °C (113 °F)
for Pi=169 mW, Ii=52 mA, T5 60 °C (140 °F)
for Pi=169 mW, Ii=52 mA, T4-T1 89 °C (192.2 °F)
for Pi=242 mW, Ii=76 mA, T6 30 °C (86 °F)
for Pi=242 mW, Ii=76 mA, T5 45 °C (113 °F)
for Pi=242 mW, Ii=76 mA, T4-T1 74 °C (165.2 °F)
Equipment protection level Da
ATEX marking II 1D Ex ia IIIC T135°C Da
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012
Ignition protection “Intrinsic safety” Use is restricted to the following stated conditions
Appropriate type NBB15-U.K-N0…
Effective internal capacitance max. 110 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 200 µH ; a cable length of 10 m is considered.
General information
Use in the hazardous area see instruction manuals
Category 1G; 2G; 3G