Ürünler

Sensör Pepperl+Fuchs
Endüktif Sensör Pepperl Fuchs NJ60-FP-E2-P2-V1
29 Ocak 2019
Sensör Pepperl Fuchs
Endüktif Sensör Pepperl Fuchs NJ8-18GK-N
29 Ocak 2019
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NJ6S1+U1+N1


Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NJ6S1+U1+N1
Pepperl NJ6S1+U1+N1
NJ6S1+U1+N1

Açıklama

Pepperl Fuchs NJ6S1+U1+N1 Endüktif Sensör
Pepperl NJ6S1+U1+N1 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NJ6S1+U1+N1
Pepperl Fuchs NJ6S1+U1+N1 Yakınlık Sensörü
Inductive Sensor NJ6S1+U1+N1 Pepperl-Fuchs
Endüktif Sensör NJ6S1+U1+N1 Pepperl-Fuchs

Teknik veriler NJ6S1+U1+N1

General specifications
Switching function Normally open (NO)
Output type NAMUR with safety function
Rated operating distance 6 mm
Installation flush
Assured operating distance 0 … 4.86 mm
Reduction factor rAl 1
Reduction factor rCu 1
Reduction factor r304 0
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 … 100 Hz
Current consumption
Measuring plate not detected ≤ 1 mA
Measuring plate detected ≥ 3 mA
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
MTTFd 9191 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
FM approval
Control drawing 116-0165
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 … 100 °C (-13 … 212 °F)
Mechanical specifications
Connection type screw terminals
Information for connection A maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-section up to 2.5 mm2
Minimum core cross-section without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-section without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing material PBT
Sensing face PBT
Degree of protection IP68
Note only for non-ferrous metal
Data for application in connection with hazardous areas
Equipment protection level Ga , Gb , Da , Mb
General information
Use in the hazardous area see instruction manuals