Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NJ3-18GK-S1N
Pepperl NJ3-18GK-S1N
NJ3-18GK-S1N
Pepperl Fuchs NJ3-18GK-S1N Endüktif Sensör
Pepperl NJ3-18GK-S1N Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NJ3-18GK-S1N
Pepperl Fuchs NJ3-18GK-S1N Yakınlık Sensörü
Inductive Sensor NJ3-18GK-S1N Pepperl-Fuchs
Endüktif Sensör NJ3-18GK-S1N Pepperl-Fuchs
General specifications | ||
Switching function | Normally open (NO) | |
Output type | NAMUR with safety function | |
Rated operating distance | 3 mm | |
Installation | flush in mild steel | |
Assured operating distance | 0 … 2.4 mm | |
Actual operating distance | 2.7 … 3.3 mm typ. | |
Reduction factor rAl | 1 | |
Reduction factor rCu | 1 | |
Reduction factor r304 | 0 | |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the “exida Functional Safety Assessment” document which is available on www.pepperl-fuchs.com as an integral part of this product’s documentation. |
|
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V | |
Switching frequency | 0 … 200 Hz | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | ≤ 1 mA | |
Measuring plate detected | ≥ 3 mA | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
MTTFd | 10660 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % |